Tecres. Advancing High Tecnology

Spacer for hip

The Tecres preformed spacer for hip has a load-bearing structure in stainless steel coated with antibiotic bone cement and it resembles a femoral prosthesis.

  • Spacer-G: loaded with Gentamicin (3 sizes of head with long stem and 3 sizes of head with short stem)
  • Spacer-G Flat Stem: loaded with Gentamicin with flat stem designed to preserve the greater trochanter (3 sizes of head with long stem and 3 sizes of head with short stem)
  • Vancogenx-Space: preformed spacer loaded with Vancomycin + Gentamicin (3 sizes of head with long stem and 3 sizes of head with short stem)
  • Vancogenx-Space Flat Stem: loaded with Vancomycin + Gentamicin with flat stem designed to preserve the greater trochanter (3 sizes of head with long stem and 3 sizes of head with short stem)

Spacer Hip

Download images from surgical technique

Variants

SPACER G - short stem
With gentamicin
Available in 3 sizes of head: 46/54/60 mm

VANCOGENX SPACE - short stem
With vancomycin and gentamicin
Available in 3 sizes of head: 46/54/60 mm

SPACER G FLAT STEM - short stem
With gentamicin
Available in 3 sizes of head: 46/54/60 mm

VANCOGENX SPACE FLAT STEM - short stem
With vancomycin and gentamicin
Available in 3 sizes of head: 46/54/60 mm

SPACER G - long stem
With gentamicin
Available in 3 sizes of head: 46/54/60 mm.

VANCOGENX SPACE - long stem
With vancomycin and gentamicin
Available in 3 sizes of head: 46/54/60 mm

SPACER G FLAT STEM - long stem
With gentamicin
Available in 3 sizes of head: 46/54/60 mm

VANCOGENX SPACE FLAT STEM - long stem
With vancomycin and gentamicin
Available in 3 sizes of head: 46/54/60 mm

Benefits
Accessories
    • Ready to use device
    • Maintenance of joint space and mobilisation
    • Effective in situ release of antibiotic
    • Deambulation with partial weight-bearing
    • Facilitation of definitive re-implant surgery
    • Standardized mechanical performance
    • Reduction of functional recovery time after the two stage procedure
  • Spacer Hip Trial
    Trial spacer to select the right size of spacer before implant it.

    Spacer Hip XL Trial
    Trial spacer to select the right size of spacer before implant it.

    Spacer Flat Stem Trial
    Trial spacer to select the right size of spacer before implant it.

    Spacer Flat Stem XL Trial
    Trial spacer to select the right size of spacer before implant it.

Related content / Publications

Preformed acrylic bone cement spacer loaded with antibiotics: use of two-stage procedure in 10 patients because of infected hips after total replacement. Acta Orthop Scand. 2001 Dec;72(6):591-4.

Authors: Magnan B, Regis D, Biscaglia R, Bartolozzi P.
Publication date: December 2001

Link
Endovascular repair of a pseudo-aneurysm of the common femoral artery after revision total hip arthroplasty. Emerg Radiol. 2007 Sep;14(4):233-6. Epub 2007 Apr 4.

Authors: D'Angelo F, Piffaretti G, Carrafiello G, Tozzi M, Caronno R, Castelli P, Zatti G.
Publication date: April 2007

Link
Septic arthritis of the hip caused by nontyphi Salmonella after urinary tract infection. Am J Emerg Med. 2009 Mar;27(3):373.e5-373.e8.

Authors: Muñoz-Mahamud E, Casanova L, Font L, Fernández-Valencia JA, Bori G.
Publication date: May 2009

Link

Related content / Interviews

The preformed spacer

The preformed spacer

Giovanni Calonego
Tecres Scientific Coordinator